Generated by All in One SEO v4.8.9, this is an llms.txt file, used by LLMs to index the site. # QCM Sensors QCM Crystals, Quartz Crystal Microbalance Devices and Accessories ## Sitemaps - [XML Sitemap](https://qcm-sensors.com/sitemap.xml): Contains all public & indexable URLs for this website. ## Posts - [QCM News, Events and Publications](https://qcm-sensors.com/qcm-news-events-and-publications/) - [Join Us at the XXIX. Congress of the Hungarian Biophysical Society in Budapest, Hungary](https://qcm-sensors.com/events/conferences/join-us-at-the-xxix-congress-of-the-hungarian-biophysical-society-in-budapest-hungary/) - [Join Us at the 33rd Anniversary World Congress on Biosensors in Busan, Korea: Innovation and Collaboration in Biosensing](https://qcm-sensors.com/events/join-us-at-the-33rd-anniversary-world-congress-on-biosensors-in-busan-korea-innovation-and-collaboration-in-biosensing/) - [Sponsoring Elsevier's Bio-Sensing Technology conference in 2022](https://qcm-sensors.com/events/sponsoring-elseviers-bio-sensing-technology-conference-in-2022/) - [International Meeting on Chemical Sensors - Matrafured 2022](https://qcm-sensors.com/events/international-meeting-on-chemical-sensors-matrafured-2022/) - [QCM 3000 - Biosensor System for Combined "Wet" and "Dry" Mass Measurements](https://qcm-sensors.com/news/qcm-i-3000-biosensor-system-for-combined-wet-and-dry-mass-measurements/) - [Introducing QCM-I Net, MicroVacuum’s new solution for multi-channel QCM-D measurements with unlimited options](https://qcm-sensors.com/news/introducing-qcm-i-net-multi-channel-qcmd-with-unlimited-channels-option/) - [The Measurement of Protein and Nano-Particle Adsorption using QCM-I](https://qcm-sensors.com/publications/application-notes/the-measurement-of-protein-and-nano-particle-adsorption-using-qcm-i/) - [Combining QCM-I and OWLS Measurements to Understand Polymer Multilayer Deposition Processes](https://qcm-sensors.com/publications/application-notes/combining-qcm-i-and-owls-measurements-to-understand-polymer-multilayer-deposition-processes/) - [QCM-I Setup for Measuring the Effect of Humidity on Thin Films](https://qcm-sensors.com/publications/tech-notes/qcm-i-setup-for-measuring-the-effect-of-humidity-on-thin-films/) - [Fluidic Configurations for QCM-I / QCM-D](https://qcm-sensors.com/publications/tech-notes/fluidic-configurations-for-qcm-i-qcm-d/) - [Measuring Thick Coconut Oil Films and Cleaning using QCM-I](https://qcm-sensors.com/publications/application-notes/measuring-thick-coconut-oil-films-and-cleaning-using-qcm-i/) - [Synchronizing QCM-I (QCM-D) Measurements Using the Digital IO Port](https://qcm-sensors.com/publications/synchronizing-qcm-i-qcm-d-measurements-using-the-digital-io-port/) - [Measurement of Polymer Multilayer Deposition using QCM-I](https://qcm-sensors.com/publications/application-notes/measurement-of-polymer-multilayer-deposition-using-qcm-i/) - [The Quartz Crystal Microbalance in Soft Matter Research: Fundamentals and Modeling (Soft and Biological Matter)](https://qcm-sensors.com/publications/the-quartz-crystal-microbalance-in-soft-matter-research-fundamentals-and-modeling-soft-and-biological-matter/) - [Handbook of Biosensors and Biochips (2 Volume set)](https://qcm-sensors.com/publications/handbook-of-biosensors-and-biochips-2-volume-set/) - [Label-Free Biosensing: Advanced Materials, Devices and Applications (Springer Series on Chemical Sensors and Biosensors)](https://qcm-sensors.com/publications/label-free-biosensing-advanced-materials-devices-and-applications-springer-series-on-chemical-sensors-and-biosensors/) - [Handbook of Surface Plasmon Resonance](https://qcm-sensors.com/publications/handbook-of-surface-plasmon-resonance/) - [Quartz Crystal Microbalance in Glove Box](https://qcm-sensors.com/publications/quartz-crystal-microbalance-in-glove-box/) - [QCManalysis - a modeling software for QCM-I is coming soon](https://qcm-sensors.com/modeling/qcmanalysis-a-modeling-software-for-qcm-i-is-coming-soon/) - [Biosensors 2020 is postponed to 9-12 November, 2020](https://qcm-sensors.com/events/conferences/biosensors-2020-is-postponed-to-9-12-november-2020/) - [QCM-D with extended temperature range from -40°C to +150°C](https://qcm-sensors.com/news/qcm-d-with-extended-temperature-range-from-40c-to-150c/) - [The Principles of QCM-I](https://qcm-sensors.com/publications/the-principles-of-qcm-i/) - [Biological Surfaces and Interfaces: the Mechanistic View - Sponsoring and Exhibiting](https://qcm-sensors.com/events/conferences/biological-surfaces-and-interfaces-the-mechanistic-view-sponsoring-and-exhibiting/) - [Using Complementary Acoustic and Optical Techniques for Quantitative Monitoring of Biomolecular Adsorption at Interfaces](https://qcm-sensors.com/publications/using-complementary-acoustic-and-optical-techniques-for-quantitative-monitoring-of-biomolecular-adsorption-at-interfaces/) - [Fibronectin terminated multilayer films: protein adsorption and cell attachment studies](https://qcm-sensors.com/publications/fibronectin-terminated-multilayer-films-protein-adsorption-and-cell-attachment-studies/) - [Variations in Coupled Water, Viscoelastic Properties, and Film Thickness of a Mefp-1 Protein Film during Adsorption and Cross-Linking:  A Quartz Crystal Microbalance with Dissipation Monitoring, Ellipsometry, and Surface Plasmon Resonance Study](https://qcm-sensors.com/publications/variations-in-coupled-water-viscoelastic-properties-and-film-thickness-of-a-mefp-1-protein-film-during-adsorption-and-cross-linking -a-quartz-crystal-microbalance-with-dissipation-monitorin/) - [A comparative study using OWLS and QCM-I chips coated with waveguide material](https://qcm-sensors.com/publications/a-comparative-study-using-owls-and-qcm-i-chips-coated-with-waveguide-material/) - Hydration, viscoelastic properties and dominant structure of thin polymer layers on the surface of waveguide material were evaluated using optical waveguide lightmode spectroscopy (OWLS) and quartz crystal microbalance (QCM) methods. The fundamentally different principles of the two applied label-free biosensors enable to examine analyte layers from complementary aspects, e.g. to determine the amount of bound water in hydrated layers. - [Gamry Announces Exclusive Distribution of MicroVacuum’s Quartz Crystal Microbalance Instruments which Include Impedance and Dissipation Measurement](https://qcm-sensors.com/press-releases/gamry-announces-exclusive-distribution-of-microvacuums-quartz-crystal-microbalance-instruments-which-include-impedance-and-dissipation-measurement/) - [Speakers announced for the Biosensors 2020 Congress](https://qcm-sensors.com/events/conferences/speakers-announced-for-the-biosensors-2020-congress/) - [Biosensors 2020 - Call for Papers Open](https://qcm-sensors.com/events/conferences/biosensors-2020-call-for-papers-open/) - [Biodetection & Biosensors Summit 2019](https://qcm-sensors.com/events/conferences/biodetection-biosensors-summit-2019/) - The Biodetection, Biosensors and Wearables 2019 conference will be held in San Diego, CA from April 1, 2019 through April 2, 2019. - [A comparative study of protein adsorption on titanium oxide surfaces using in situ ellipsometry, optical waveguide lightmode spectroscopy, and quartz crystal microbalance / dissipation](https://qcm-sensors.com/publications/a-comparative-study-of-protein-adsorption-on-titanium-oxide-surfaces-using-in-situ-ellipsometry-optical-waveguide-lightmode-spectroscopy-and-quartz-crystal-microbalance-dissipation/) - [Simultaneous determination of optical and acoustic thicknesses of protein layers using surface plasmon resonance spectroscopy and quartz crystal microweighing](https://qcm-sensors.com/publications/simultaneous-determination-of-optical-and-acoustic-thicknesses-of-protein-layers-using-surface-plasmon-resonance-spectroscopy-and-quartz-crystal-microweighing/) - [Google Dataset Search is now available for researchers and journalists](https://qcm-sensors.com/news/google-dataset-search-is-now-available-for-researchers-and-journalists/) - [Electrochemistry 2018](https://qcm-sensors.com/events/conferences/electrochemistry-2018/) - [Biointerfaces International 2018](https://qcm-sensors.com/events/conferences/biointerfaces-international-2018/) - Biological surfaces are one of the most innovative and expanding areas of science: These biointerfaces represent surfaces where synthetic materials and biological systems interact with each other; with vast opportunities of groundbreaking development, discoveries and innovations. The Biointerfaces International 2018 conference at the Zurich University of Zurich in August 14-16, 2018 aims to connect relevant application areas of science & engineering and brings together senior scientists, researchers, corporations and academia. - [Bioaffinity Sensor Based on Nanoarchitectonic Films](https://qcm-sensors.com/publications/bioaffinity-sensor-based-on-nanoarchitectonic-films/) - [Attachment of Pathogenic Prion Protein to Model Oxide Surfaces](https://qcm-sensors.com/publications/attachment-of-pathogenic-prion-protein-to-model-oxide-surfaces/) - [Elongation kinetics of polyglutamine peptide fibrils: a quartz crystal microbalance with dissipation study.](https://qcm-sensors.com/publications/elongation-kinetics-of-polyglutamine-peptide-fibrils-a-quartz-crystal-microbalance-with-dissipation-study/) - [Formation of supported bacterial lipid membrane mimics](https://qcm-sensors.com/publications/formation-of-supported-bacterial-lipid-membrane-mimics/) - [The Density and Refractive Index of Adsorbing Protein Layers](https://qcm-sensors.com/publications/the-density-and-refractive-index-of-adsorbing-protein-layers/) - [5th International Conference on Bio-Sensing Technology](https://qcm-sensors.com/events/5th-international-conference-on-bio-sensing-technology/) - [12th Annual Bio-Europe Partnering Conference](https://qcm-sensors.com/events/conferences/12th-annual-bio-europe-partnering-conference/) ## Pages - [Home](https://qcm-sensors.com/) - Shop for QCM sensor crystals with a variety of coating and metalization options and quartz crystal microbalance devices and accessories. - [Home](https://qcm-sensors.com/) - Shop for QCM sensor crystals with a variety of coating and metalization options and quartz crystal microbalance devices and accessories. - [Contact us](https://qcm-sensors.com/contact-us/) - [Sales Terms And Conditions](https://qcm-sensors.com/sales-terms-and-conditions/) - [Terms Of Use](https://qcm-sensors.com/terms-of-use/) - [Privacy Policy](https://qcm-sensors.com/privacy-policy/) - [About](https://qcm-sensors.com/about-us/) - [Cookie Policy](https://qcm-sensors.com/cookie-policy/) - [Payment Success](https://qcm-sensors.com/payment-success/) - [Payment Fail](https://qcm-sensors.com/payment-fail/) - [Payment Checkout](https://qcm-sensors.com/payment-checkout/) - [Submit Your Listing](https://qcm-sensors.com/submit-listing/) - [Edit Your Listing](https://qcm-sensors.com/edit-listing/) - [Select Your Plan](https://qcm-sensors.com/pricing-plan/) - [Dashboard](https://qcm-sensors.com/listing-author/) - [Payment Confirmation](https://qcm-sensors.com/payment-confirmation/) - [Payment Failed](https://qcm-sensors.com/payment-failed/) - [Affiliate Disclosure](https://qcm-sensors.com/affiliate-disclosure/) - [Shipping](https://qcm-sensors.com/shipping/) - [QCM Products](https://qcm-sensors.com/quartz-crystal-microbalance-products/) - Shop for QCM sensor crystals with a variety of coating and metalization options and quartz crystal microbalance devices and accessories. - [Comparing QCM-D devices: QCM-I vs QCM-I Mini](https://qcm-sensors.com/comparing-qcm-d-devices-qcm-i-vs-qcm-i-mini/) - [Maintenance](https://qcm-sensors.com/maintenance/) ## Products - [14 mm QCM Crystal (5pcs)](https://qcm-sensors.com/product/14-mm-qcm-crystal/) - AT cut quartz crystals with optically polished surfaces. They have wrap around electrode geometry for one-sided contacting. These sensors are highly stable at overtone frequencies. All QCM sensors are quality tested and referred to in many scientific publications. Additional information: Customized 3MHz and 10MHz probes are available on request - please consult with Semilab for details and quotation. 1 sensor ordering option is available upon request, please cotact Semilab for quotation. - [QSHE-open Electrochemical Cuvette](https://qcm-sensors.com/product/qshe-open-electrochemical-cuvette/) - The QSHE-open is a static electrochemical cuvette for the QCM-I systems. It fits the thermal controlled internal QCM-I chambers and the QMH-ext. external sensor holders. It has an open 5ml solution volume chamber made from PEEK and comes with an Ag/AgCl reference and a Pt wire counter electrode. The sealing is made with VITON O rings. The lid also has fittings for gas in- and out-lets, or to allow for real-time sample additions. - [QSHE-014 Electrochemical Flow Cell For QCM-I / QCM-D Systems](https://qcm-sensors.com/product/qshe-014-electrochemical-flow-cell-for-qcm-i-qcm-d-systems/) - [QSH-Window Flow Cell For Optical Bright-field Microscopy, Raman, and Inverse Microscopy](https://qcm-sensors.com/product/qsh-window-flow-cell-for-optical-bright-field-microscopy-raman-and-inverse-microscopy/) - [QSH-014 standard flow cell](https://qcm-sensors.com/product/qsh-014-standard-flow-cell/) - [QSH-Dip sensor holder for immersion applications](https://qcm-sensors.com/product/qsh-dip-sensor-holder-for-immersion-applications/) - QCM sensor holder for immersion application. The external immersion sensor-holder exposes the sensing side of the crystal and is otherwise sealed, so that it can be immersed into a beaker of liquid, or can be used flat and filled with a small volume of solution. - [25.4 mm QCM Crystal (5pcs)](https://qcm-sensors.com/product/25-4-mm-qcm-crystal/) - [QCM-I (QCM-D)](https://qcm-sensors.com/product/qcm-i-qcm-d/) - The QCM-I (QCM-D) measuring unit is a high-sensitivity mass sensor, which measures the change in frequency of a quartz crystal resonator and as a label free biosensor it measures the “wet mass” of the adsorbed layer in processes occurring at or near the sensor surface. The measuring principle is based on impedance analysis of the quartz crystal. The resonant frequency and the bandwidth of the resonant conductance curve are determined. The bandwidth or full width at half maximum, (FWHM) is direct correlation with the quality factor (Q) which is by definition the inverse of the well known dissipation (D). - [QCM-I Mini (QCM-D)](https://qcm-sensors.com/product/qcm-i-mini-qcm-d/) - The QCM-I Mini (QCM-D) measuring unit is a high-sensitivity mass sensor, which measures the change in frequency of a quartz crystal resonator and as a label free biosensor it measures the "wet mass" of the adsorbed layer in processes occurring at or near the sensor surface. - [QCM-I OWLS NET](https://qcm-sensors.com/product/qcm-i-owls-net/) ## Categories - [Scientific Publications](https://qcm-sensors.com/topics/publications/) - [Events](https://qcm-sensors.com/topics/events/) - [Conferences](https://qcm-sensors.com/topics/events/conferences/) - [Press Releases](https://qcm-sensors.com/topics/press-releases/) - [QCM Theory](https://qcm-sensors.com/topics/publications/qcm-theory/) - [Dry-Wet Mass](https://qcm-sensors.com/topics/publications/dry-wet-mass/) - [News](https://qcm-sensors.com/topics/news/) - [Modeling](https://qcm-sensors.com/topics/modeling/) - [Application Notes](https://qcm-sensors.com/topics/publications/application-notes/) - [Tech Notes](https://qcm-sensors.com/topics/publications/tech-notes/) ## Tags - [Elsevier](https://qcm-sensors.com/tag/elsevier/) - [Italy](https://qcm-sensors.com/tag/italy/) - [Protein adsorption](https://qcm-sensors.com/tag/protein-adsorption/) - [Protein conformation](https://qcm-sensors.com/tag/protein-conformation/) - [Antibody reaction](https://qcm-sensors.com/tag/antibody-reaction/) - [Albumin](https://qcm-sensors.com/tag/albumin/) - [Fibrinogen](https://qcm-sensors.com/tag/fibrinogen/) - [Hemoglobin](https://qcm-sensors.com/tag/hemoglobin/) - [Titanium oxide](https://qcm-sensors.com/tag/titanium-oxide/) - [Surface properties](https://qcm-sensors.com/tag/surface-properties/) - [Adsorption](https://qcm-sensors.com/tag/adsorption/) - [Optical waveguide technique](https://qcm-sensors.com/tag/optical-waveguide-technique/) - [Ellipsometry](https://qcm-sensors.com/tag/ellipsometry/) - [Quartz crystal microbalance](https://qcm-sensors.com/tag/quartz-crystal-microbalance/) - [quartz crystal microbalance with dissipation monitoring (QCM-D)](https://qcm-sensors.com/tag/quartz-crystal-microbalance-with-dissipation-monitoring-qcm-d/) - [surface plasmon resonance (SPR)](https://qcm-sensors.com/tag/surface-plasmon-resonance-spr/) - [optical waveguide lightmode spectroscopy (OWLS)](https://qcm-sensors.com/tag/optical-waveguide-lightmode-spectroscopy-owls/) - [dual polarization interferometry (DPI)](https://qcm-sensors.com/tag/dual-polarization-interferometry-dpi/) - [hydration](https://qcm-sensors.com/tag/hydration/) - [polymer brush](https://qcm-sensors.com/tag/polymer-brush/) - [supported lipid bilayer (SLB)](https://qcm-sensors.com/tag/supported-lipid-bilayer-slb/) - [protein adsorption kinetics](https://qcm-sensors.com/tag/protein-adsorption-kinetics/) - [conformational changes](https://qcm-sensors.com/tag/conformational-changes/) - [PMOXA](https://qcm-sensors.com/tag/pmoxa/) - [QCM-I](https://qcm-sensors.com/tag/qcm-i/) - [OWLS](https://qcm-sensors.com/tag/owls/) - [HUVEC](https://qcm-sensors.com/tag/huvec/) - [Zurich](https://qcm-sensors.com/tag/zurich/) - [Switzerland](https://qcm-sensors.com/tag/switzerland/) - [Biological surfaces](https://qcm-sensors.com/tag/biological-surfaces/) - [ETH Zurich](https://qcm-sensors.com/tag/eth-zurich/) - [University of Zurich](https://qcm-sensors.com/tag/university-of-zurich/) - [PLL-g-PEG](https://qcm-sensors.com/tag/pll-g-peg/) - [Nature.com](https://qcm-sensors.com/tag/nature-com/) - [Ulm](https://qcm-sensors.com/tag/ulm/) - [Germany](https://qcm-sensors.com/tag/germany/) - [Google](https://qcm-sensors.com/tag/google/) - [Google Dataset Search](https://qcm-sensors.com/tag/google-dataset-search/) - [Google Scholar](https://qcm-sensors.com/tag/google-scholar/) - [Mefp-1 Protein Film](https://qcm-sensors.com/tag/mefp-1-protein-film/) - [dry mass](https://qcm-sensors.com/tag/dry-mass/) - [wet mass](https://qcm-sensors.com/tag/wet-mass/) - [SPR](https://qcm-sensors.com/tag/spr/) - [QCM](https://qcm-sensors.com/tag/qcm/) - [biosensors2020](https://qcm-sensors.com/tag/biosensors2020/) - [Biosensor 2020](https://qcm-sensors.com/tag/biosensor-2020/) - [qcm-d](https://qcm-sensors.com/tag/qcm-d/) - [theory](https://qcm-sensors.com/tag/theory/) - [gamry](https://qcm-sensors.com/tag/gamry/) - [microvacuum](https://qcm-sensors.com/tag/microvacuum/) - [Glove Box](https://qcm-sensors.com/tag/glove-box/) - [Controlled Atmosphere Chamber](https://qcm-sensors.com/tag/controlled-atmosphere-chamber/) - [Biosense](https://qcm-sensors.com/tag/biosense/) - [QCM-I Net](https://qcm-sensors.com/tag/qcm-i-net/) - [multi-channel QCM-D](https://qcm-sensors.com/tag/multi-channel-qcm-d/) - [optical biosensor](https://qcm-sensors.com/tag/optical-biosensor/) - [acoustic biosensor](https://qcm-sensors.com/tag/acoustic-biosensor/) - [Matrafured](https://qcm-sensors.com/tag/matrafured/) - [HUngary](https://qcm-sensors.com/tag/hungary/) - [Visegrad](https://qcm-sensors.com/tag/visegrad/) - [Spain](https://qcm-sensors.com/tag/spain/) - [Sitges](https://qcm-sensors.com/tag/sitges/) - [Biosensors 2023](https://qcm-sensors.com/tag/biosensors-2023/) - [Hungarian Biophysical Society](https://qcm-sensors.com/tag/hungarian-biophysical-society/) - [Faculty of Science at Eötvös Loránd University](https://qcm-sensors.com/tag/faculty-of-science-at-eotvos-lorand-university/) ## Product categories - [QCM Crystals](https://qcm-sensors.com/product-category/qcm-crystals/) - [QCM-I (QCM-D) Systems](https://qcm-sensors.com/product-category/qcm-biosensor-devices/) - [QCM Accessories](https://qcm-sensors.com/product-category/qcm-accessories/) ## Product tags - [QCM-I](https://qcm-sensors.com/product-tag/qcm-i/) - [QCM-I Mini](https://qcm-sensors.com/product-tag/qcm-i-mini/) - [QCM-D](https://qcm-sensors.com/product-tag/qcm-d/) - [OWLS](https://qcm-sensors.com/product-tag/owls/) - [QCM-I NET](https://qcm-sensors.com/product-tag/qcm-i-net/)